201
Reference Manual
00809-0100-4811, Rev DA
Appendix C: Rosemount 3300 Series with HART
®
to Modbus
®
Converter
January 2015
Rosemount 3300 Series with HART
®
to Modbus
®
Converter
C.11.3 ABB TotalFlow
Figure C-10. Wiring Diagram for Connecting 3300 Modbus to ABB TotalFlow
Table C-20. Parameter Values (in case of ABB TotalFlow)
The Input Register Base Number needs to be added to the Input Register address of the
Rosemount 3300 Series Transmitter. In this case, register 1302 needs to have 1303 entered as
the address etc.
C.11.4 Thermo Electron Autopilot
Figure C-11. Wiring Diagram for Connecting 3300 Modbus to Thermo Electron Autopilot
Parameter Value
Baud Rate 9600
Floating Point Format Code 0
RTU Data Type 16 Bit Modicon
Input Register Base Number 1
+ 8 to + 30 Vdc