Reference Manual
00809-0100-4811, Rev DA
Appendix A: Reference Data
January 2015
Reference Data
Weight
Flange: depends on flange size
Coaxial probe: 0.67 lb/ft. (1 kg/m)
Rigid single lead probe (0.3 in./8 mm): 0.27 lb/ft. (0.4 kg/m)
Rigid single lead probe (0.5 in./13 mm): 0.71 lb/ft. (1.06 kg/m)
Segmented Rigid Single Lead probe (0.5 in./13 mm): 0.71 lb/ft (1.06 kg/m)
Rigid twin lead probe: 0.40 lb/ft. (0.6 kg/m)
Flexible single lead probe: 0.05 lb/ft. (0.07 kg/m)
Flexible twin lead probe: 0.09 lb/ft. (0.14 kg/m)
End weight: 0.88 lb (0.40 kg) for single probes, 1.3 lb (0.60 kg) for twin probes
Engineered solutions
When standard model codes are not sufficient to fulfil requirements, please consult the factory
to explore possible Engineered Solutions. This is typically, but not exclusively, related to the
choice of wetted materials or the design of a process connection. These Engineered Solutions
are part of the expanded offerings and may be subject to additional delivery lead time. For
ordering, factory will supply a special R-labeled numeric option code that should be added at
the end of the standard model string. See example model string below.
Example Model String: 3301-H-A-1-S-1-V-5A-E-33-00-RC-I5-M1W3C1-R1234
A.3.4 Chamber / pipe installations
Rosemount 9901 chamber
Rosemount 9901 allows external mounting of process level instrumentation. It supports a
variety of process connections, and optional drain and vent connections. The Rosemount 9901
chamber is designed to the ASME B31.3 standard, and is Pressure Equipment Directive (PED)
compliant. Use option code XC to order together with the 3300 Series transmitters.
The probe length to use for a Rosemount 9901 chamber can be calculated with this formula:
Side-and-side dimension:
Probe length = centre-to-centre dimension + 19 in. (48 cm)
Side-and-bottom dimension:
Probe length = centre-to-centre dimension + 4 in. (10 cm)
Use a centering disc the same diameter as the chamber if the probe length > 3.3 ft. (1 m). See
Probe type in chamber considerations and Centering discs on page 139 for which probe and
disc to use.